Special techniques
Challenging clinical setups
Step-by-step guidance and illustrative overviews for complex treatment setups, including why these techniques are used and how to simulate and deliver them.
Special technique · Transplant conditioning
Total Body Irradiation (TBI)
Delivers a uniform whole-body dose to ablate malignant bone marrow and provide immunosuppression before stem cell or bone marrow transplant.
Indications: AML, ALL (high-risk), CML, non-Hodgkin lymphoma, Hodgkin lymphoma, myelodysplastic syndrome.
- Eradicates residual malignant cells in sanctuary sites (CNS, testes) that chemotherapy cannot reliably reach.
- Provides profound immunosuppression to prevent graft rejection of the transplanted marrow.
- Creates marrow space for engraftment of donor stem cells.
- Typically combined with chemotherapy conditioning (cyclophosphamide, etoposide, or fludarabine).
- Myeloablative regimens commonly prescribe 12 Gy in 6 twice-daily fractions; non-myeloablative uses lower single doses.
- 1
Confirm prescription
Verify diagnosis, transplant protocol, total dose, fractionation, dose rate (typically ≤10 cGy/min), and organ-at-risk limits (lungs, lenses, kidneys).
- 2
Choose positioning
Adults usually stand or sit at extended SSD in a TBI jig; pediatric or frail patients lie supine. Arms crossed over the chest help shield the lungs.
- 3
Measure patient thickness
Record AP and lateral thickness at head, chest, abdomen, pelvis, and legs to design tissue compensators for dose homogeneity (±10%).
- 4
Define dose point
Prescribe to midplane at the umbilicus; calculate monitor units at the extended treatment distance (commonly 4–6 m).
- 5
Design lung shielding
Create custom lung blocks to cap total lung dose below ~10–12 Gy and reduce the risk of interstitial pneumonitis.
- 6
Reproducible setup
Use a fixed jig with handles, head holder, and indexed supports; document SSD, patient height, and field size for daily reproducibility.
- 7
Mark and image
Place setup marks on stable landmarks; acquire simulation CT or 2D setup films at treatment distance to verify beam geometry and compensator fit.
- 8
Calculate and verify
Compute MUs accounting for extended-SSD output factors, inverse square, and compensator transmission; perform phantom verification before treatment.
- 1
Pre-treatment check
Independently verify prescription, plan, MUs, compensators, lung blocks, and dose rate before the first fraction.
- 2
Daily setup
Position patient in the jig, attach compensators, and place lung blocks; confirm alignment with lasers and setup marks.
- 3
Beam-on
Deliver AP/PA or bilateral large fields at the prescribed low dose rate to the entire body.
- 4
In-vivo dosimetry
Place diodes, OSL, or TLDs at multiple body sites (head, chest, abdomen, pelvis, legs) to confirm delivered dose and adjust compensators if out of tolerance.
- 5
Fractionation
Deliver twice-daily fractions separated by at least 6 hours over 2–4 days; keep dose rate low throughout.
- 6
Organ shielding
Add lens shielding for cataract risk and testicular/ovarian shielding when clinically appropriate.
- 7
Supportive care
Monitor for nausea, fever, and hypotension; administer antiemetics and hydration as needed.
- 8
Document
Record delivered dose, in-vivo readings, vital signs, and tolerance for each fraction.
- Critical organs at risk: lungs, lenses, gonads, kidneys, and liver.
- Dose rate ≤10 cGy/min is essential to reduce pneumonitis and other toxicities.
- Compensators and thickness-based dose correction keep whole-body dose within ±10%.
- Acute effects: nausea, vomiting, fever, mucositis, and transient erythema.
- Long-term risks: cataracts, infertility, growth delay in children, and secondary malignancy.